You can add bridge port extenders (BPEs) to existing Extended Edge
					Switching ring topologies. You can add
				BPEs anywhere in the ring.
			To add a BPE:
		
		- 
				Disconnect the cable between the
					two BPEs in the ring at the desired insertion point, which allows the ring to
					enter the severed state, and then re-converge into two operational
					cascades.
			
 - 
				Connect the new BPE to the same
					connection points disconnected previously. 
				
					If you have auto-configuration enabled (enable vpex
				auto-configuration), you are finished. If you want to manually configure the rest of the
						setup (ensure that auto-configuration is disabled), continue with the
						following steps.
				 
			 - 
				(If you are connecting at the
					point where the configured cascades were joined, do not perform this step)
					Unconfigure the cascade port of the BPE connecting the new BPE using the
					procedure in Removing Bridge Port Extenders from Slot Assignments.
				
					
Note   
To find where the configured cascades were joined, use the 
show vpex
				topology { port
				port_num} {summary | detail} command, and see where the dynamically created cascade ports ("d" flag)
						start on the cascade(s).
 
				 
			 - 
				Configure the new BPE using the
					procedure in Manually Configuring Bridge Port Extenders starting with step 3.
			
 
		Configuring a new VPEX port/slot in a ring destroys the ring, and changes the
			configured cascades that formed it. For the new cascades, one ends where the new
			slot/BPE was added and the other ends at the next BPE that is connected to the cascade
			with the new slot/BPE.